HV50 AUTOCLAVE HIRAYAMA
HV50 AUTOCLAVE HIRAYAMA
HV50 AUTOCLAVE HIRAYAMA
Hover to Zoom

Sell HV50 AUTOCLAVE HIRAYAMA



Specification of HV50 AUTOCLAVE HIRAYAMA

Hirayama HV-50 Upright Autoclave (50 Liter)

 

Specifications

 

MODEL

HV-50

 
TEMPERATURE 
Operating Range

105ºC to 135ºC

 
Display Range

137ºC

 
Warming Range

45ºC to 60ºC

Agar Dissolution

Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC 
(programmable for up to 20 hours to prevent coagulation)

GAUGE PRESSURE 
Operating Range

3 to 30 psi (0.02 to 0.206MPa)

 
Maximum Allowable

38 psi (0.26MPa)

 
TIMER 
Sterilization

1 to 250 minutes

Delayed Auto-start

Program autoclave to start 1 minute to 7 days later

DIMENSIONS 
Overall (W x D x H)

20" x 21" x 41"
(51 cm x 53 cm x 104 cm)

 
Chamber
(Diameter x Height)

50 liters
11.8" x 28.0" (30 cm x 71 cm)

 
SAFETY DEVICES

Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker

PROGRAMS 
1. For agar

Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion

2. For liquids

Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion

3. For solids

Heating -> Sterilization -> Exhaust (fast, default) -> Completion

4. For melting agar or for faster start-up

Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion

ACCESSORIES 
Stainless steel

Mesh wire baskets, buckets (pails), and round test tube racks

Factory or field installed

Floating (load) sensor, digital printer, and data logger

POWER 
Source

120V, 50/60 Hz (220V/240V available)

Consumption

2000 watts (20000VA)

 
SHIPPING WEIGHT

180 lb (82 kg)

  • Space-saving design with lid opening upward.
  • Programmable auto-start for initiating a cycle up to 1 week later.
  • Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
  • Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
  • One-touch lever to easily open and close chamber lid.
  • Programmable rate of steam exhaust.
  • Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
  • In-process display shows status and progress of sterilization cycle.
  • Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
  • Unique accessory: Floating sensor to monitor load temperature.
  • Sterilization timer is activated only when load temperature reaches set temperature.
  • Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
  • Memory backup system retains user-programmed parameters even in case of power failure.